Uptimecat

SLA calculator

Enter an uptime target and see how much downtime it allows per day, week, month, quarter and year. Use it to set realistic goals and to read a provider's promise.

What the numbers mean

An uptime target looks small but allows more downtime than people expect. At 99 percent, a 30-day month can lose over seven hours. At 99.9 percent it is about 43 minutes. At 99.99 percent it is a little over four minutes.

Each extra nine cuts the budget by ten times. It also costs more, because you need redundancy, faster detection and tested failover. Pick the lowest target that still fits your users.

Reference values for a 30-day month

TargetAllowed downtime per month
99%7 h 12 min
99.5%3 h 36 min
99.9%43 min 12 s
99.95%21 min 36 s
99.99%4 min 19 s

How to read an SLA

  • Look at the measurement period. A monthly figure is stricter than a yearly one.
  • Check what counts as downtime. Many agreements exclude planned maintenance.
  • Check who measures it. A provider's own status page is not the same as an independent check from outside.
  • See what you get when the target is missed. It is often a small service credit, not compensation for lost sales.

Measure your own uptime

Set a target, then measure against it. Uptimecat records every check, so you can compare real uptime with the promise you made to your customers. Use maintenance windows for planned work and a public status page to show the result. For the full workflow, see SLA monitoring.

Setting an internal target

Many teams set an internal target that is stricter than the promise they make to customers. If you promise 99.9 percent, aim for 99.95 percent inside, so one bad month does not break the agreement. Review the real figure every month and look at which incidents used most of the budget. A few long outages usually matter more than many short ones.

Frequently asked questions

Which month length does the calculator use?

30 days for the month, 90 for the quarter and 365 for the year. A provider may use calendar months.

Is 100 percent possible?

Not in practice. Even excellent systems have rare outages, so treat a 100 percent promise with care.

Should a short blip count?

It depends on your agreement. Define it up front, for example a failed check followed by a failed retry.